434 Ascent Xtrata Pro User's Guide
Note The defined regions also control the number of pages to be processed by OCR
in Ascent Xtrata Pro Server. If you want to limit the number of pages, you should
disable the appropriate page options in each locator that requires OCR results.
Access
Select “Outside the regions” or “Inside the regions”. If “Outside the regions” is
selected, all manually entered regions are denied areas. This means the locator
operates on the entire document except the regions that have been defined. If “Inside
the regions” is selected, all manually entered regions are Allow regions. This means
the locator is restricted to inside the specified regions.
List of regions
The properties of a region are as follows:
Figure 6-89. List with Two Sample Regions
Name
Name of the region. This is useful if many regions are used. Click in the name
column to rename a region.
Page
A region can be restricted to a page or a set of pages. Click in the “Page” column
and select another value from the list.
Left
The Left coordinate of the region in mm or as a percentage. The value can be
changed manually in absolute units or by adding a percentage sign. For example
choosing 30% for Left means the left edge of the region always begins at 30% of
the document width as measured from the left.
Top
The Top coordinate of the region in mm or as a percentage. The value can be
changed manually in absolute units or by adding a percentage sign. For example
choosing 30% for Top means the top edge of the region always begins at 30% of
the document height as measured from the top.